International Residential Code
One book for building a house, from footings to wiring.
What it covers
The IRC covers detached one- and two-family homes and townhouses up to three stories above grade, each with its own exit. Anything bigger falls under the IBC.
It is written so most houses can be built from tables without an engineer: span tables for joists and rafters, wall-bracing tables, and footing sizes by soil type. It bundles energy, mechanical, fuel gas, plumbing and electrical chapters, so a builder can work from one book. Many states adopt it but swap the plumbing or electrical chapters for their own codes.
Read the official text
Opens the publisher's or government's own copy in a new tab.
How it is organized
- Ch. 1–2Administration and definitionsPermits, inspections and defined terms.Open 2021 ↗
- Ch. 3Building planningThe heart of the code: local design criteria, fire separation from property lines and garages, light and ventilation, ceiling heights, safety glass, bedroom escape windows, stairs, guards, smoke and CO alarms, and sprinklers.Open 2021 ↗
- Ch. 4FoundationsFootings, foundation walls, waterproofing, drainage and crawl spaces.Open 2021 ↗
- Ch. 5FloorsFloor framing and span tables, concrete slabs, and decks.Open 2021 ↗
- Ch. 6Wall constructionWood and cold-formed steel framing, wall bracing against wind and earthquakes, masonry and insulated concrete forms.Open 2021 ↗
- Ch. 7Wall coveringDrywall, siding, stucco, water-resistive barriers and flashing around windows and doors.Open 2021 ↗
- Ch. 8–9Roof framing and roof coveringsRafters, trusses, attic ventilation, shingles and other roof coverings, and reroofing.Open 2021 ↗
- Ch. 10Chimneys and fireplacesMasonry and factory-built fireplaces and chimneys.Open 2021 ↗
- Ch. 11Energy efficiencyInsulation levels, window performance, air sealing and duct sealing. This chapter repeats the residential part of the same-year IECC.Open 2021 ↗
- Ch. 12–23MechanicalFurnaces, heat pumps, bath and kitchen exhaust, dryer vents, ductwork, combustion air, boilers, water heaters and solar thermal systems.Open 2021 ↗
- Ch. 24Fuel gasGas piping sizes and materials, appliance connections and venting. Drawn from the IFGC.Open 2021 ↗
- Ch. 25–33PlumbingFixtures, water heaters, water supply, drains, vents, traps and storm drainage.Open 2021 ↗
- Ch. 34–43ElectricalServices, branch circuits, wiring methods, GFCI and AFCI protection, receptacles, lighting and pools. Drawn from the NEC.Open 2021 ↗
- Ch. 44 & appendicesReferenced standards and optionsAppendices (for example tiny houses or straw-bale construction) apply only where adopted.Open 2021 ↗
Common answers
Where to look in the official text.
| Snow load, wind speed, frost depth and other local design values | Table R301.2(1), filled in by your local jurisdiction |
| Fire separation between the house and an attached garage | Section R302.6 |
| How close to the property line before walls need fire rating | Section R302.1 |
| Where safety glass is required | Section R308 |
| Bedroom emergency escape window size | Section R310 |
| Stair rise, run, width and headroom | Section R311.7 |
| Guard height and window fall protection | Section R312 |
| Smoke alarms | Section R314 |
| Carbon monoxide alarms | Section R315 |
| Deck framing, ledgers and joist spans | Section R507 |
| Wall bracing | Section R602.10 |
| Attic ventilation | Section R806 |
| Insulation R-values by climate zone | Table N1102.1.3 |
| Clothes dryer exhaust | Section M1502 |
| GFCI and AFCI protection | Section E3902 |
Section numbers refer to the 2021 edition; most are the same in 2018 and 2024.
How editions differ
- 2024Energy chapter updated to match the 2024 IECC; many structural tables refreshed.
- 2021Energy chapter tightened to match the 2021 IECC, the largest residential efficiency step in a decade.
- 2018 / 2015Still common (for example Tennessee and Minnesota on 2018; Michigan, Kentucky and North Carolina on 2015). Energy requirements are noticeably less stringent.
Where it is in force
Locations on this site that use this code, by edition.
This guide is an original plain-language summary, not the code itself. Section numbers can shift between editions and local amendments, so always confirm against the official text adopted where you build.