International Energy Conservation Code & ASHRAE 90.1
How much insulation, how airtight, how efficient.
What it covers
The IECC is two codes in one book. The residential provisions cover houses and apartment buildings up to three stories; the commercial provisions cover everything else. Each starts by placing your county in a climate zone, then sets requirements for insulation, windows, air sealing, HVAC, water heating and lighting.
For commercial buildings, the code lets designers comply with ASHRAE Standard 90.1 instead. Many states also write their own energy codes based on one of these.
Read the official text
Opens the publisher's or government's own copy in a new tab.
How it is organized
Chapter links open the 2021 edition. Commercial chapters are prefixed C, residential chapters R.
- C1–C3Commercial: scope, definitions, climate zonesWhich buildings are commercial, and how to find your climate zone.Open 2021 ↗
- C4Commercial energy efficiencyBuilding envelope, mechanical systems, service water heating, lighting and electrical power, plus extra-efficiency credits and the whole-building performance option.Open 2021 ↗
- C5Commercial existing buildingsWhat applies to additions, alterations, repairs and changes of use.Open 2021 ↗
- R1–R3Residential: scope, definitions, climate zonesSame structure for houses and low-rise apartments.Open 2021 ↗
- R4Residential energy efficiencyInsulation and window tables, air-leakage testing, duct testing, mechanical ventilation, and the choice of compliance path: prescriptive, performance or Energy Rating Index.Open 2021 ↗
- R5Residential existing buildingsAdditions, alterations and repairs.Open 2021 ↗
Common answers
Where to look in the official text.
| Which climate zone am I in? | Section R301 / C301 (county tables) |
| Required insulation R-values for a house | Table R402.1.3 |
| Blower-door air leakage test for a house | Section R402.4.1.2 |
| Duct leakage testing | Section R403.3 |
| Whole-house mechanical ventilation | Section R403.6 |
| Commercial envelope requirements | Tables C402.1.3 and C402.1.4 |
| Lighting power allowances | Section C405.3.2 |
| Extra efficiency credits for commercial buildings | Section C406 |
| Using ASHRAE 90.1 instead | Section C401.2 |
Section numbers refer to the 2021 IECC.
How editions differ
- 2024 IECC / 90.1-2022Further efficiency gains. Electric-vehicle and electric-ready provisions sit in optional appendices that jurisdictions may adopt.
- 2021 IECC / 90.1-2019The biggest residential efficiency step in a decade and the most widely adopted current edition.
- 2018 / 2015 / 2009Still in force in many states; older editions require less insulation and do not always require air-leakage testing.
Where it is in force
Locations on this site that use this code, by edition.
This guide is an original plain-language summary, not the code itself. Section numbers can shift between editions and local amendments, so always confirm against the official text adopted where you build.