Building Codes in Force

NFPA 101 Life Safety Code

Getting people out safely, occupancy by occupancy.

National Fire Protection Association (NFPA)9 jurisdictions5 parts explained4 quick answers

What it covers

The Life Safety Code focuses on protecting occupants: exits, fire protection features and alarm systems. Its distinctive structure gives each occupancy two chapters, one for new and one for existing buildings. Several states use it as their fire or life safety code, and US hospitals and nursing homes must meet it to take part in Medicare and Medicaid.

Read the official text

Opens the publisher's or government's own copy in a new tab.

Current and recent editionsReadFree with accountNFPA free access

How it is organized

  1. Ch. 1–5Administration and fundamentalsGoals, definitions and the performance-based design option.
  2. Ch. 6Classification of occupancyDefines each occupancy and how mixed uses are handled.
  3. Ch. 7Means of egressDoors, stairs, ramps, exit capacity, travel distance measurement, signs and lighting.
  4. Ch. 8–10Protection features, systems and finishesFire barriers and smoke barriers, sprinklers and alarms, and interior finish.
  5. Ch. 12–43Occupancy chaptersPaired new and existing chapters: assembly (12–13), educational (14–15), day care (16–17), health care (18–19), ambulatory health care (20–21), detention (22–23), houses (24), hotels (28–29), apartments (30–31), board and care (32–33), mercantile (36–37), business (38–39), industrial (40), storage (42), and rehabilitation of existing buildings (43).

Common answers

Where to look in the official text.

Exit capacity and stair widthChapter 7 (Section 7.3)
Travel distance limitsThe 'Means of Egress' section of each occupancy chapter
Requirements for an existing hospitalChapter 19
Requirements for a new apartment buildingChapter 30

Where it is in force

Locations on this site that use this code, by edition.

NFPA 101-2015 / NFPA 1Louisiana
NFPA 101-2015Illinois
NFPA 1 & NFPA 101Florida, Maryland, New Hampshire

This guide is an original plain-language summary, not the code itself. Section numbers can shift between editions and local amendments, so always confirm against the official text adopted where you build.