International Fire Code
Fire safety for buildings in use, not just when they are built.
What it covers
The IFC is usually enforced by the fire marshal or fire department. It applies to new and existing buildings and covers how they are used and maintained: keeping exits clear, testing sprinklers and alarms, fire department access, storing hazardous materials, and running risky operations such as welding or fuel dispensing.
It works hand in hand with the IBC. Many of its system requirements repeat the IBC's, so a building that meets one generally meets the other.
Read the official text
Opens the publisher's or government's own copy in a new tab.
How it is organized
- Ch. 1–2Administration and definitionsFire code official's powers, operational permits, inspections and defined terms.Open 2021 ↗
- Ch. 3General requirementsEveryday hazards: open burning, storage near buildings, housekeeping, vacant buildings and outdoor cooking.Open 2021 ↗
- Ch. 4Emergency planningFire safety and evacuation plans, drills and staff training by occupancy.Open 2021 ↗
- Ch. 5Fire service featuresFire apparatus access roads, address numbers, key boxes, water supply and hydrants, and in-building radio coverage for responders.Open 2021 ↗
- Ch. 6Building services and systemsElectrical hazards, heating appliances, elevator recall, kitchen hoods and emergency power.
- Ch. 7–8Fire-resistance and interior finishesKeeping rated walls and doors intact, and limits on decorations and furnishings.
- Ch. 9Fire protection and life safety systemsWhen sprinklers, standpipes, alarms and extinguishers are required, and how they are tested and maintained.Open 2021 ↗
- Ch. 10Means of egressKeeping exits usable in existing buildings: locks, obstructions, exit signs and lighting.Open 2021 ↗
- Ch. 11Upgrades for existing buildingsRetroactive requirements that apply even when no work is planned.
- Ch. 12Energy systemsBattery energy storage, solar panels, fuel cells and generators.
- Ch. 20–40Special occupancies and operationsSpecific hazards such as fuel dispensing, tents, high-piled storage, fire safety during construction, hot work and plant-extraction facilities.
- Ch. 50–67Hazardous materialsGeneral rules plus one chapter per class: flammable liquids, LP-gas, compressed gases, explosives and fireworks, toxics, oxidizers and others.
Common answers
Where to look in the official text.
| Fire apparatus access road width and turnarounds | Section 503 and Appendix D |
| Required fire flow and hydrant spacing | Section 507 and Appendices B and C |
| Key box (Knox box) requirements | Section 506 |
| Where sprinklers are required | Section 903.2 |
| Where fire alarms are required | Section 907.2 |
| Portable fire extinguishers | Section 906 |
| Battery energy storage systems | Section 1207 |
| Tents and temporary structures | Chapter 31 |
| High-piled storage in warehouses | Chapter 32 |
| Fire safety on a construction site | Chapter 33 |
| Welding and hot work | Chapter 35 |
| How much hazardous material can be stored | Tables 5003.1.1(1) and (2) |
Section numbers refer to the 2021 edition.
How editions differ
- 2024Updates energy storage and other hazard provisions.
- 2021Adds rules for cannabis and other plant-extraction facilities and greatly expands battery storage requirements.
- 2018Introduces the energy systems chapter.
Where it is in force
Locations on this site that use this code, by edition.
This guide is an original plain-language summary, not the code itself. Section numbers can shift between editions and local amendments, so always confirm against the official text adopted where you build.